Radio Systems CT-2002 Instructions d'exploitation Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
FOR MASTER TIME SYNC VIA TOP-of-HOUR RESET
wire timer displays Top-of-Hour in for accurate time readout.
Note: T.O.H. input must be used to offset timer by one or more
seconds. Use IR remote control progam option 10 consult
manual page 11 for more information.
SERIAL INPUT
TERMINATION
RJ-45 OUT
RJ-45 IN
GND
+15V DC IN
RJ-45 SHIELD TO GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 4” & 2” or Desktop (Desktop Shown)
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 4” & 2” or Desktop (Desktop Shown)
Ancillary I/O
16- Ground
17- Down Time Closure at “0”
18- Top-of-Hour Input
19- Ground
20- +15V DC
Remote Control
6- Ground
7- Start
8- Stop
9- Reset
10- Mode
Clock Triggers
11- Ground
12- Time Closure #1
13- Time Closure #2
14- Time Closure #3
15- Time Closure #4
Serial Synchronizing Data
1- Serial In +
2- Serial In -
3- Ground
4- Serial Out -
5- Serial Out +
REMOTE CONTROL BARRIER STRIP PIN-OUTS
CT-2002 Large
FOR MASTER TIME SYNC VIA RADIO SYSTEMS or SMPTE SERIAL DATA
wire timer displays serial in with Radio Systems or SMPTE Time-of-Day
serial input for accurate time readout. Accurate time will be read by all
serially connected displays. Time may be offset by one or more hours
- use IR remote control progam option 4 consult manual page 10 for
more information.
Use a straight thru RJ-45 patch cable (from either RJ-45 connector) if
this clock is being fed with remote master time sync and if downstream
displays are not required to display remote timer information.
Repeat up to 35 displays.
Note: final display serial line must be terminated with a
150 resisitor (use terminator DIP switch on large clock.)
Use a crossover RJ-45 patch cable to slave Time-of-Day
and/or timer displays to downstream units.
Via the IR remote control enter the program mode and select option 3 for serial
time-of-day format. Select “rs1” for time-of-day only re-display from the master
clock. Select “rs2” for time-of-day and timer re-display from the master clock.
You must use a crossover RJ-45 patch cable if this display is the
master (first clock) in the serial chain or, if you want downstream
clockcs to display remote timer as well as Time-of-Day
PC Clock Input Sync
Note: Software/hardware
kit available (Radio Systems
part # 16117) to update
Windows PC clocks via USB
from the CT-2002
serial data stream
Radio Systems, Inc. CT2002 Manual
Page 23
Serial Clock/Timer Connections between CT2002 stand-alone Models
Master/Slave Interconnection via RJ-45 Patch Cable Connections
Straight thru (Time-of-Day only)
RJ-45 Display Cable.
Crossover (Time-of-Day and Timer)
RJ-45 Display Cable.
RJ-45 Patch Cord Wiring
Vue de la page 22