Remote Control Connections
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
G
ND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
G
ND
DOW
N TIME
CL
OSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-4
5 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SH
IELD TO
GN
D
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
START
TOH RESET
STOP
RESET
MODE
Time Closures
Pull to Ground
Ground on Timer Remote Barrier Strip
GROUND
Use IN4148 or
other general
purpose
signal diodes
Use any general purpose
SPST momentarty push
button or two
StudioHub+ 3BUT panels
Position 1 (in timer mode)
MEM 1
MEM 2
MEM 3
MEM 4
MEM 5
MEM 6
Position 2 (in timer mode)
Position 3 (in timer mode)
Position 4 (in timer mode)
Position 5 (in timer mode)
Position 6 (in timer mode)
Connections
to Timer Remote
Barrier Strip
STOP
RESET
MODE
START
START
START
STOP
STOP
START
RESET
MODE
MODE
MODE
MODE
To recalled stored memory positions 1 thru 6 via wired remote:
Wire to remote terminals shown for Thin/Desktop/2” & 4” models.
Note that steering diodes (not supplied) must be installed.
GND
+15V DC IN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Ancillary I/O
16- Ground
17- Down Time Closure at “0”
18- Top-of-Hour Input
19- Ground
20- +15V DC
Remote Control
6- Ground
7- Start
8- Stop
9- Reset
10- Mode
Clock Triggers
11- Ground
12- Time Closure #1
13- Time Closure #2
14- Time Closure #3
15- Time Closure #4
Serial Synchronizing Data
1- Serial In +
2- Serial In -
3- Ground
4- Serial Out -
5- Serial Out +
REMOTE CONTROL BARRIER STRIP PIN-OUTS
TOH RESET
STOP
RESET
MODE
Time Closures
pull to ground
START
GROUND
1 2 3 4 5 6 7 8
BACK
DIP
SWITCHES
(UP IS ON)
SERIAL DATA OU
T +
SERIAL DATA OUT -
GROUND
START SWIT
CH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GROUND
AHEAD
DC TO CLOCKS
10 Hz TO CLOCKS
GROU
ND
COM
MON
N. O. CONTACT
ANTENNA
15V DC IN
1 Hz OUT
TO
IMPULSE
DRIVER
TO
ANALOG
CLOCKS
TOP
OF HOUR
CLOSURE
MODEL CT-2002 GPS Part No. 14411
START
TOP OF HOUR
RELAY CLOSURE
STOP
RESET
MODE
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
START
TOH RESET
STOP
RESET
MODE
Time Closures
pull to ground
DOWN TIME CLOSURE AT “0”
GND
TOP OF HOUR RESET INPUT
TIME CLOSURE 4
TIME CLOSURE 3
TIME CLOSURE 2
TIME CLOSURE 1
GND
SERIAL OUT -
SERIAL OUT +
+9V DC IN
GND
GND
START SW
STOP SW
RESET SW
MODE SW
GND
SERIAL IN -
SERIAL IN +
J4 J6
CT-4INCH
& CT-2INCH
CT-THIN
CT-DESK
CT-GPS