Radio Systems, Inc. CT-2002 Manual
Page 7
Radio Systems, Inc. CT-2002 Manual
Page 7
To Utilize as a Slaved Timer Display as well as a slaved clock dis-
play. (CT-2002 Display units only):
1. Consult page 11 for Setup function programming, and choose selection
3 option “RS2” for slave timer operation.
2. Provide serial data from any CT-2002 display unit whose timer display you
want to slave. Connect the serial data output terminals of the up-stream
CT-2002 display to the serial data input terminals of the slave display. Use
either terminal strip or RJ-45 connectivity (consult wiring diagram on page 20
& 21.)
3. Place the slave display in the clock mode and confirm that the “SYNC” front
panel LED on the slave display is lit and that the slave displays shows the
Time-of-Day from the up-stream unit.
4. In the “Clock” mode, the time-of-day on the slave display will now synchro-
nize to the up-stream stand alone display (regardless of what mode is being
displayed on the stand-alone upstream display.)
5. Place the slave display in the timer mode and press the “MEM 6” button on
the IR remote control. Confirm that the SYNC LED on the slave lights and
that the slave display shows the timer data from the up-stream display unit.
6. To return the slave display to none-slaving timer (stand-alone) functionality,
press the “RESET” button on the IR remote control with the slave display in
the timer mode. The “SYNC” LED will extinguish and the timer display will
reset to 00:00, allowing local (IR and parallel) timer control.
7. To return to slave timer operation, push the “MEM 6” button on the IR
remote control with the slave display in the timer mode. The “SYNC” LED
will (re)illuminate and the display will synchronize to the up-stream stand-
alone timer display.
8. Additional timers “downstream” from this slave timer may be wired to slave
to this timers display, or function as Time-of-Day displays and independent
stand-alone timer displays. Consult the wiring diagram on page 20 (RJ-45
patch cord wiring) or 21 (twisted pair wiring) for specific wiring configura-
tions.
Wired Remote Control
All front panel controls are available on the rear barrier strip connector.
Contacts are momentary / pull-to-ground.
See attached wiring diagram for connections - page 18.